
For a Worcester attic, ENERGY STAR recommends R-60 if there's no insulation now, or adding R-49 if you already have 3 to 4 inches. That's guidance for climate zone 5A, not the code. We'll go up, measure what you have and tell you what it takes to get there, on a free estimate.
R-value is how hard insulation makes it for heat to get through. The higher the number, the slower your heat leaks out in winter. It's the number printed on the batt or the bag.
Every material gives a different R for each inch. So two attics with the same depth of insulation can have very different R-values. Layers add up: new insulation on top of old counts toward the total.
R-value only works when the insulation is put in right. Squashed batts, gaps and wet spots all lose part of it. Insulation slows heat, but it doesn't stop air. Warm air leaking through gaps in the attic floor goes straight past it. That's why we seal the gaps before we insulate. See air sealing.
Worcester is in climate zone 5A. Worcester County is 5A on every IECC climate map, both the 2006-2018 map and the 2021/2024 one. Massachusetts' amendments to the 2021 IECC put the whole state in 5A.
Worcester averages about 6,600 heating degree days a year (1991-2020 average). A degree day measures how far a day's average temperature falls below 65 degrees, so that number means a long heating season. Summer adds only about 500 cooling degree days. Winter is what your attic insulation is mostly working against.
For a zone 5 home, ENERGY STAR recommends:
These levels follow the 2021 IECC's zone 5 row. They're guidance, not the code. We aim for them.
If your attic is short of these levels, it's usually the best place to start. How the work itself goes is on our attic insulation page. If you're paying through Mass Save, their discounts are explained on Mass Save insulation rebates.
Loose cellulose gives roughly R-3.7 an inch, and loose fiberglass roughly R-2.5. Those are rules of thumb for checking insulation already in an attic, not product ratings. They still show the main point: fiberglass needs more depth than cellulose to reach R-49.
For new work, the bag sets the exact depth. Every bag of blown insulation has a coverage chart. For each R-value, it lists how many bags the area needs, how deep to blow it, and how deep it must still be after it settles.
Two brands of the same material can differ, too. So we don't go by a number from memory. We install to the depth the maker's chart gives for the R-value in your estimate.
See blown cellulose, blown fiberglass and the brands we install.
Measure the depth, then multiply by the per-inch rule of thumb above for your kind of fill.
Loose fiberglass is fluffy and usually white, yellow or pink. Cellulose is gray and looks like shredded paper. On batts, the R-value is often printed on the facing. Measure in several spots, because old insulation is rarely even.
One warning. If the fill looks like gray-brown pebbles, it may be vermiculite. Don't dig into it to measure. It may contain asbestos and shouldn't be disturbed until a lab has tested it. See what to do about vermiculite.
You can also skip the tape measure. We'll measure it for you on the free estimate.
Massachusetts is in climate zone 5A (225 CMR 22.00). We'll confirm the required insulation levels for your home with your building inspector.
Which code applies depends on the job. In Worcester the Specialized Code applies only to new construction. Additions and renovations follow the standard Stretch Energy Code. What that means for your project is on HERS ratings and the Stretch Code.
Closed-cell spray foam and the stronger foam boards, polyiso and XPS, give the most R per inch of the common insulations used in homes. Open-cell foam gives less per inch than closed-cell. Among loose fills, cellulose gives more per inch than fiberglass.
The most per inch isn't the best choice everywhere. Per inch matters where space is tight: sloped ceilings, knee walls, shallow rafter bays and rim joists. An open attic floor has room for depth, so blown-in usually does the job there.
Compare them on closed-cell spray foam, open vs. closed cell, rigid foam board and types of insulation.
R-38 slows heat more than R-30, because a higher number is better. Both are below the attic levels recommended for zone 5A, though. If your attic has either one, you have room to add more.
Yes, as long as the old insulation is dry, in decent shape and not vermiculite. The new layer counts toward your total. If the old insulation is wet or damaged, we find the cause first and it may have to come out. See insulation removal.
Loose fill settles, which is why the bag lists a settled depth. Insulation that gets squashed, soaked or pulled apart loses part of its R-value. If yours looks thin, matted or stained, measure it or have us look at it.
No. A wall can only hold what fits in the space between the studs, so walls are planned differently. Insulating the walls of an existing house is its own job, covered on our wall insulation page.
We'll measure what you have, tell you its R-value and what it takes to reach the zone 5A level, and put it in a written estimate. Ask for your free estimate today.
Licensed & insured · Free estimates