No insulation is fireproof, but some types won't burn and others slow a fire down. In Worcester we use mineral wool and treated cellulose where fire resistance counts. We put a fire barrier over exposed foam and block open wall cavities in old balloon-framed houses. We also keep insulation clear of chimneys and recessed lights.
You can choose insulation that won't burn or that slows a fire, and we match it to the spot in your house.
Tell us what you're trying to protect and ask for a free estimate. We'll walk the house and say which material goes where.

If your house is balloon-framed, fire and smoke can travel from the cellar to the attic inside the walls. That older style runs the studs the full height of the house with no stop at each floor.
Fire blocking closes those paths. We pack the open cavities tight at the cellar and attic floor. We also seal the chases around pipes, wires and old flues. We use mineral wool and fire-rated sealant or foam, never ordinary foam.
We do this before we insulate the wall, so the new insulation isn't filling a cavity that fire could use. We check from the cellar and the attic, where the tops and bottoms of the walls show.
Blocking those cavities also cuts the air moving through them. See air sealing, wall insulation and rim joist insulation for how the pieces fit together.
Spray foam burns, so exposed foam needs a thermal or ignition barrier over it wherever your inspector requires one. A thermal barrier is the heavier protection, for foam next to living space. An ignition barrier is the lighter one, for spots like attics and crawl spaces.
Our usual fix is an intumescent coating. It's sprayed over the foam and swells when heated, which keeps flame off the foam. Our installed price is $1 to $1.50 per square foot of foam surface coated. That covers coating exposed foam in attics, crawl spaces, garages and metal buildings to meet fire code.
The coating thickness required and whether you need an ignition barrier or a full thermal barrier rating both move the price. The spray foam cost page has the rest, and the free estimate gives the exact price for your house.
If you're deciding on foam in the first place, read closed cell spray foam and spray foam insulation.
Insulation can't touch a chimney or flue. The building code and the chimney maker's instructions set a gap, and we keep to it.
To hold insulation back from the chimney, we build a sheet-metal collar around it. We seal the collar to the framing with high-temperature, fire-rated sealant, then insulate right up to the collar. That also closes the open gap between a chimney and the framing, which is a fire path.
With a recessed light, the rating on the fixture decides. An IC-rated fixture can be covered with insulation. A non-IC fixture can't, because it needs clearance to shed heat. For those we keep insulation back as far as the fixture requires until the light is replaced or covered. The fix can be an IC-rated fixture, which your electrician swaps in, or a fire-rated cover over the can.
Either way we seal the opening with fire-rated caulk or foam sealant so air and heat stop leaking into the attic. See attic insulation for the rest of the job.
Tell us before we start. Old knob-and-tube wiring can be a fire hazard when insulation touches it, so an electrician checks it first. We plan the work around what the electrician finds.
That depends on the condition of what's there. The insulation removal page shows how we decide.
It can. The material, the thickness and the access to the space all move the price. We price it after we see the job, so ask for a free estimate and we'll give you a written price.
Tell us about the chimney, the old walls or the foam you're worried about. We'll look at the house and give you a written scope and price.
Licensed & insured · Free estimates